Home Precision Environment Airflow & HVAC Validation Air Flow Transducer Model 6333
Airflow Transducer Model 6333 product image thumbnail
Airflow Transducer Model 6333 workflow diagram thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
Airflow Transducer Model 6333 application overview thumbnail
KanomaxStationary Airflow Transducer

Air Flow Transducer Model 6333

Compact stationary anemometer for remote monitoring of air velocity, temperature and humidity. Model 6333 supports 15 interchangeable probe types, switchable analogue output and RS-485 communication for equipment, facility and IoT monitoring installations.

Velocity range
0.01–50.0 m/sProbe dependent
Measured parameters
Velocity / T / RHProbe dependent
Outputs
4–20 mA or 0–5 VPlus RS-485
Power
12–24 V DCApprox. 3 W
15 probe types Remote monitoring RS-485 DIN-rail option
4–20 mA 0–5 V RS-485 DIN-rail mounting

Model and Probe Overview

ComponentMeasurement capabilityRange / configurationSelection guidance
6333-00 main unitStationary transmitter with analogue and digital outputs12–24 V DC; switchable 4–20 mA or 0–5 V; RS-485Select the probe, cable length, power option and mounting accessories for the installation.
Velocity probesDirectional or omnidirectional air-velocity measurement0.01–25.0, 30.0 or 50.0 m/s depending on probeChoose by velocity range, directivity, response time, temperature resistance and probe geometry.
Velocity + temperature probesSimultaneous velocity and temperature measurementUp to 100°C or 120°C depending on probeSuitable where process-air temperature must be recorded with velocity.
Velocity + temperature + humidity probeThree-parameter remote monitoring0.01–25.0 m/s; 0–60°C; 5–95% RHUse Model 0975-31 for combined environmental monitoring.

Key Features

Fifteen compatible probes

Supports directional and omnidirectional probes for velocity-only, velocity-and-temperature, or velocity-temperature-humidity measurement.

Wide velocity coverage

Probe-dependent velocity ranges extend from 0.01 m/s to 25, 30 or 50 m/s for low-flow monitoring through higher-velocity process applications.

High-temperature capability

Selected probes support operating and compensation temperatures up to 100°C or 120°C for demanding equipment and process-air measurements.

Analogue and digital outputs

A DIP switch selects 4–20 mA current output or 0–5 V voltage output, while RS-485 supports digital communication.

Compact stationary design

The approximately 100 × 60 × 25 mm, 200 g main unit can be integrated into equipment or installed using the optional DIN-rail fixing base.

Remote multiparameter monitoring

Suitable probe configurations allow simultaneous output of air velocity, temperature and humidity for facilities, factories, data centres and IoT systems.

Technical Specifications

ParameterUnitValue / Description
MAIN UNIT — MODEL 6333-00
Instrument typeStationary airflow transducer / anemometer for remote monitoring
Compatible probes15 probe types for velocity, temperature and humidity measurements
Air-velocity rangem/s0.01–25.0, 0.01–30.0 or 0.01–50.0 depending on probe
Velocity accuracyProbe dependent; generally ±2% or ±3% of reading, or ±0.02 m/s, whichever is greater
Temperature range°C0–60, 0–100 or 0–120 depending on probe
Humidity range% RH5–95 with probe 0975-31
ResolutionVelocity: 0.01 m/s to 9.99 m/s and 0.1 m/s from 10.0–50.0 m/s; temperature: 0.1°C; humidity: 0.1% RH
Display unitsm/s, °C and % RH
OUTPUTS AND POWER
Analogue outputSwitchable by DIP switch: 4–20 mA current output, maximum 250 Ω load, or 0–5 V voltage output
Digital interfaceRS-485
Power supplyV DC12–24; optional AC adaptor accepts 100–240 V AC input
Power consumptionWApproximately 3 under the manufacturer’s stated reference condition
ENVIRONMENT AND PHYSICAL
Operating environment0–60°C; 2–95% RH; no condensation
Storage environment−20–70°C; 2–95% RH; no condensation
Dimensions W × D × HmmApproximately 100 × 60 × 25
WeightgApproximately 200
Standard accessoriesInstruction manual and terminal block
Optional itemsProbe, probe cable, AC adaptor, DIN-rail fixing base, probe fixing jig and probe mounting tape

Velocity accuracy, response time and temperature compensation are probe dependent. Confirm the selected probe model, cable length, output setting, power arrangement and calibration scope before ordering.

Applications

Ventilation and facility monitoring

Provides continuous velocity, temperature or humidity data from selected points in building ventilation systems.

Cooling-air monitoring

Supports remote observation of supply, return and equipment cooling airflow where the chosen probe range and mounting method are suitable.

Process and equipment airflow

Integrates airflow data into production equipment, environmental chambers and process monitoring systems.

Remote data acquisition

Uses analogue outputs or RS-485 communication for controller, data-logger and monitoring-system integration.

Heated-air measurement

Selected probes support velocity and temperature measurement in environments up to 100°C or 120°C.

Three-parameter monitoring

The 0975-31 probe supports simultaneous velocity, temperature and relative-humidity monitoring.